Product: Alternator: ECO 46 -VL/4 A (F Class) Control System: DSE 7320
INTRODUCTION

Aksa is committed to providing the most effective solution to the Data Center industry with the power it takes from engineering, production, distribution, and customer-oriented experience and knowledge. We are constantly improving designs, products and infrastructure to offer the highest level of reliability for Emergency Power Systems. While serving the industry in hundreds of countries Globally, we design our products and systems in line with the needs of Data Center practitioners at the center of our focus. Aksa generator group provides continuity, reliability and ideal performance for Data Centers. For all generator groups produced, preliminary product testing and factory manufacturing testing are performed according to the Uptime Institute's Tier Standards

Certificate
  ISO 14001-2004
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AC 3000
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model CUMMINS - QSK78-G9
Alternator Made and Model Mecc Alte - ECO 46 -VL/4 A (F Class)
Control Panel Model DSE 7320
Canopy UNKNOWN
3 Phase, 50 Hz, PF 0.8
Voltage STANDBY RATING (ESP) DCP Rating Standby Amper
kVA kW kVA kW
400/231 3000 2400.00 2750 2200.00 4330.25
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.

Data Center Continuous (DCC) : The maximum power which a generating set is capable of delivering while supplying a variable or continuous electrical load and during unlimited run hours. Depending on the sites to supply and the availability of reliable utility.
ENGINE SPECIFICATIONS
Engine CUMMINS
Engine Model QSK78-G9
NO. OF CYLINDERS AND BUILD 18 cylinders - V type
BORE AND STROKE mm 170 X 190
TOTAL DISPLACEMENT L 77.6
Aspiration Turbo Charged and AfterCooled
COMPRESSION RATIO 15.5:1
RATED SPEED (RPM) d/dk 1500
OIL CAPACITY L 466
Standby Power (kW/HP) 2539/3404
DCP Rating (kW/HP) 2072/2777
Block Heater QTY
2
Block Heater Power (Watt)
3000
Fuel Type
Diesel
Injection Type and System
Direct
Type of Fuel Pump
Cummins HPI-PT
Governor System
Electronic
Operating Voltage (Vdc)
24 Vdc
Battery and Capacity (Qty/Ah)
6x143
Charge Alternator (A)
55
Cooling Method
Water Cooled
Coolant Capacity (engine only / with radiator) (lt)
166.6/
Air Filter
Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
528
Fuel Cons. Prime With %75 Load (lt/hr)
406
Fuel Cons. Prime With %50 Load (lt/hr)
291
ALTERNATOR SPECIFICATIONS
Manufacturer Mecc Alte
Alternator Made and Model ECO 46 -VL/4 A (F Class)
Frequency (Hz) Hz 50
Power (kVA) kVA 2500
Design   Brushless
Voltage V 400
Phase 3
A.V.R. DER1
Voltage Regulation (+/-) 0.5
Insulation System H
Protection IP23
Rated Power Factor 0.8
WEIGHT COMP. GENERATOR (Kg) 5120
SIZE and WEIGHT
Open Type DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
1
CANOPY DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
UNKNOWN
1 0 0 0 0
STANDARD SPECIFICATIONS
Water cooled diesel engine
Radiator and mechanical fan
Protective cage to prevent rotating and touching hot parts
Electric starter and charge alternator
Battery (lead acid), cables and stand
Engine block water heater
Steel chassis and anti-vibration wedges
Fuel tank separate from the group (Açıkset group)
Flexible fuel connection hoses
Alternator with single bearing and H insulation class
Industrial capacity muffler and flexible steel compensator
Electronic battery charger
Operating and installation instructions
The frequency and voltage regulation of the groups lifts 100% load according to NFPA110 in accordance with ISO 8528-5.
 
OPTIONAL EQUIPMENTS

Remote radiator cooling
• Fuel-water separator filter
• Oil heater

ALTERNATOR
• Anti-condensation heater
• Bigger Power rate alternator
• Output Breaker

CONTROL PANEL
• Automatic synchronization and power control system (multiple parallel generator)
• Continuous parallel system with the network
​​​​​​​• Network synchronization system
​​​​​​​• Remote communication and control
• Remote alarm panel
• Alarm output relays
​​​​​​​• Earth leakage, single generator
• Charging ammeter

TRANSFER BOARD
​​​​​​​• Three or four-pole ATS system
​​​​​​​• Three or four-pole motorized output breaker

AUXILIARY EQUIPMENT
• Main Fuel Tank
• Automatic or manual fuel filling system
• Oil drain, electric pump
​​​​​​​• Low and high fuel level alarm
• Exhaust muffler, built-in type
​​​​​​​• Enclosure cabinet; soundproof type or open area type
• Air duct adapter (radiator front)
• Motorized roller shutter (air inlet and outlet circuit)
• Soundproof duct (air inlet and outlet circuit)
• Tool kit (for maintenance)
​​​​​​​• Maintenance kit for 1500/3000 working hours
​​​​​​​• Antifreeze and engine lubricating oil (for -30 ° C ambient temperature)

Control System: DSE 7320
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
Devices
DSE, model 7320 Auto Mains Failure control module Static battery charger Emergency stop push button and fuses for control circuits
CONSTRUCTION and FINISH
Comonents installed in sheet steel enclosure.
Phosphate chemical, pre-coating of steel provides corrosion resistant surface
Polyester composite powder topcoat forms high gloss and extremely durable finish
Lockable hinged panel door provides for easy component access
INSTALLATION
Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility.
GENERATING SET CONTROL UNIT
The DSE 7320 conrol module is a standard addition to our generator sets from 220 kVA upwards and it has been designed to start and stop diesel andgas generating sets that include electronic and non electronic engines.
The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch.
The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel.
STANDARD SPECIFICATIONS
Microprocessor controlled
- 132 x 64 pixel LCD display makes information easy to read
- Front panel programming and also via PC software
- Soft touch membrane keypad and five key menu navigation
- Remote communications via RS232, RS485 and ethernet.
- Event logging (50) showing date and time
- Multiple date and time engine exercise mode and maintenance scheduler
- Engine block heater control.
- Controls; stop, manuel, auto, test, start, mute lamb test/transfer to generator, transfer to mains, menu navigation.
Instruments
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time Battery volts
Engine maintenance due

GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
Earth current
kW
Pf
kVAr
kWh, kVAh, kVArh
Phase sequence

MAINS
Voltage (L-L, L-N)
Frequency
Protection Circuits
WARNING
Charge failure
Battery under voltage
Fail to stop
Low fuel level (opt.)
kW over load
Negative phase sequence
Loss of speed signal

PRE-ALARMS
Low oil pressure
High engine temperature
Low engine temperature
Over /Under speed
Under/over generator frequency
Under/over generator voltage
ECU warning

SHUT DOWNS
Fail to start
Emergency stop
Low oil pressure
High engine temperature
Low coolant level
Over /Under speed
Under/over generator frequency
Under/over generator voltage
Oil pressure sensor open
Phase rotation

ELECTRICAL TRIP
Earth fault
kW over load
Generator over current
Negative phase sequence

Options
High oil temperature shut down
Low fuel level shut down
Low fuel level alarm
High fuel level alarm

EXPANSION MODULES
Editional LED module (2548)
Expension relay module (2157)
Expansion input module (2130)
Standards
Elecrical Safety / EMC compatibility

BS EN 60950 Electrical business equipment
BS EN 61000-6-2 EMC immunity standard
BS EN 61000-6-4 EMC emission standard
STATIC BATTERY CHARGER
Battery charger is manufactured with switching-mode and SMD technology and it has high efficincy.
Battery charger models' output V-I characteristic is very close to square
2405 has fully output shot circuit protection and ıt can be used as a current source.
2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives.
The charger is fitted with a protection diode across the output.
Charge fail output is available.
Connect charge fail relay coil between positive output and CF output.
Input: 196-264V.
Output: 27,6V 5A or 13,8V 5A.
Canopy: UNKNOWN
STANDARD SPECIFICATIONS


CANOPY MODEL UNKNOWN
WIDTH mm. 0
LENGTH mm. 0
HEIGHT mm. 0
TANK CAPACITY (lt.) Lt. 0